ELICA NT-FLAME-GR-DO Montaje Y Modo De Empleo página 75

Ocultar thumbs Ver también para NT-FLAME-GR-DO:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 122
4 - Press the knob (3-T) again for 5 seconds;the crown (L)
flashes, then turns off, indicating that you have exited the
filter settings menu
NB = you automatically exit the menu after 1 minute in any
case
Anti-grease filter saturation warning
L2 + L3 flash when maintenance of the anti-grease filter is
required
Active carbon filter saturation warning
L1 + L4 flash when maintenance of the active carbon filter is
required
Filter saturation warning reset
After filter maintenance, press the knob (3-T) for 4 seconds:
the LED lights L switch off, confirming that they have been
reset.
Note: if the saturation warnings occur at the same time (anti-
grease and active carbon filter saturation), the reset
operation must be repeated twice.
74

Publicidad

Tabla de contenido
loading

Tabla de contenido