G Eneral Notes On Safety; Se Of The Machine For Purposes For Which It Is Intended; I Ncorrect Use; D Eclaration Of Incorporation - SUHNER QUILLmaster BEM 3 Documentación Técnica

Ocultar thumbs Ver también para QUILLmaster BEM 3:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
1. N
1.1 g
eneral notes on safety
This operation manual is applicable for the machine BEM
3.
The machine may only be handled by personnel
who are qualified.
1.2 u
se of the machine for PurPoses for
which it is intenDeD
The machine is suitable for all machining operations need-
ing axial force and torque like drilling, reverse drilling, chip
breakage, countersinking, and reverse countersinking.
This machine is specifically ideal for plant construction.
1.3 i
ncorrect use
All uses other than those described under section
1.2 are regarded as incorrect use and are there-
fore not admissible.
1.4 D
eclaration of incorPoration
The manufacturer Otto Suhner AG of Industriestrasse 10,
CH-5242 Lupfig, hereby declares for the partly completed
machinery (see reverse side for type and serial no.) that
the following fundamental requirements of the Directive
2006/42/EC are applied and fulfilled in accordance with
Annex I: 1.1.2, 1.1.3, 1.1.5, 1.2.1, 1.2.2, 1.3.7, 1.3.8.1, 1.5.1,
1.5.4, and 1.6.1. Technical documentation was generated
for the partly completed machinery in accordance with
Annex VII of the Machinery Directive. Document Agent:
I. Sebben. Authorised sites are provided with this techni-
cal documentation in paper or electronic form on justified
request. This partly completed machinery may be put into
operation only when the machine in which the partly com-
pleted machinery is to be incorporated has been ascer-
tained to fulfil the conditions under the Machinery Direc-
tive. CH-Lupfig, 12/2017.
I. Sebben/Division manager
2. c
2.1 a
ssemBly instructions
Maximum admissible machine fastening error.
The machine is fastened at the bores provided in
the housing.
Screws of quality grad 8.8 must be used. The starting tor-
que for the holding down bolt is maximum 10-12Nm.
24
S
oTES oN
aFETy
ommISSIoNINg
Connect the cables only after the machine has
been completely installed.
2.2 c

onnecting the Power to the machine

2.2.1 m
otor
Before the power is connected to the motor, position the
terminal stripe jumpers according the mains power volt-
age (230 V, 400 V, 460 V).
After the power has been connected to the motor
the direction of rotation of the working spindle has
to be checked. If the direction of rotation is incorrect, re-
verse the direction by exchanging any two power wires.
The motor is equipped with thermal protection, which is
referred to as winding protection contacts. They are of the
N/C type. The connections are located in the connection
box. In the event of overload the motor is shut down by a
contactor (not included in the scope of supply). Voltage
up to 230 V.
2.2.2 s
ensores
The drilling unit is equipped with inductive sensors which
monitor both the front and rear stroke end positions. The
sensors have been adjusted in the factory.
Type: PNP
Voltage: 10-30 DCV
Output current: 200 mA

Publicidad

Tabla de contenido
loading

Tabla de contenido