INFORMATION MENU DISPLAY - CONTINUED
Options Menu visible only with yellow (Supervisor) SmartKey.
System Menu visible with either blue (User) or yellow (Supervisor) SmartKey
1
Options
Solution
Solution In Rev
Lock Detergent
Beacon
Burst Of Power (s)
Fwd Speed Max (%)
Lock Speed Limit
Inactivity Time (min)
Impact Detect
Impact Level
System
MMC Firmware
UI Firmware
CSP190-Comm F/W
CSP190-Motor F/W
MMC S/N
UI S/N
Impact Log
*Default setting
SERVICE NOTE: Additional menus (Service and Configuration) are accessible only through service/technician mode. The service menu
allows observing operational and user parameters. The configuration menu allows adjusting machine settings. See Service Manual
for more details.
1/2021
Menu Level
2
3
Proportional*
Fixed
UK
No*
Yes
No*
Yes
On*
Off
min = 60*
max = 300
step = 60
min = 50
max = 100*
step = 10
No*
Yes
min = 1
max = 30
step = 1
default = 15
Off*
Log
Lockout
High*
Low
INSTRUCTIONS FOR USE
Notes
User selectable options
Solution mode; Proportional – solution flow
increases with speed of machine. Fixed – Solution
flow stays the same despite machine speed. UK
(United Kingdom) – solution flow is reduced to
conserve water.
Leave solution on in reverse?
Lockout detergent percentage adjustment for user?
Beacon light on/off
Burst-of-power (BOP) time span (seconds) EcoFlex
Maximum forward speed as percentage of maximum
available speed
Lockout scrub speed limit for user?
Inactivity time before putting machine in sleep mode
(minutes)
Impact detection status
Log – Impact is recorded
Lockout – Impact is recorded and User is locked
out of scrub functions (Display shows (C26)) until
machine is reset with a Supervisor key.
Impact detection sensitivity level. If nuisance
tripping occurs (i.e. driving over a floor transition),
adjust setting to low.
Main controller (mmc) firmware revision
User interface panel (ui) firmware revision
Drive controller comm firmware revision
Drive controller main/motor control firmware revision
Main controller (mmc) pcb serial number
User interface panel (ui) pcb serial number
Display list of impact events with max value,
timestamp and user id (only if enabled)
- single item view will show max values for each axis
(x,y,z)