front side (faucet side) up and off bowl gasket (see figure 2).
3
Remove the bowl gasket.
4
Remove the pump impeller from its location.
5
Pinch tube faucet: push the dispensing handle (1) and
take the pinch tube off from its seat (2) (see figure 3).
6
Gravity faucet: extract the piston and then remove the
dispensing handle (see figure 4).
7
Slide drip tray out and empty it.
7. 3. 2 CLEANING
ATTENTION
Before any disassembly and/or cleaning procedure make
sure that the dispenser is disconnected from its power
source.
IMPORTANT
Do not attempt to wash any machine components in a
dish washer.
1
Prepare at least two gallons of a mild cleaning solution of
warm (45-60 °C 120-140 °F) potable water and dishwashing
detergent. Do not use abrasive detergent.
Important: if present, follow label directions, as too strong a
solution can cause parts damage, while too mild a solution will
figure 2
figure 3
figure 4
not provide adequate cleaning.
IMPORTANT
In order to prevent any damages to the dispenser use
only a detergent suitable with plastics parts.
2
Using a brush, suitable for the purpose, thoroughly clean all
disassembled parts in the cleaning solution.
ATTENTION
When cleaning the machine, do not allow excessive
amounts of water around the electrically operated com-
ponents of the unit. Electrical shock or damage to the
machine may result.
3
Do not immerge the lighted top covers in liquid. Wash them
apart with the cleaning solution. Carefully clean their
undersides.
4
In the same manner clean the evaporator plates using a
soft bristle brush.
5
Rinse all cleaned parts with cool clean water.
7. 3. 3 SANITIZING
Sanitizing should be performed immediately prior to
starting the machine. Do not allow the unit to sit for
extended periods of time after sanitization.
Sanitization must be performed whenever the distributor is
put back into operation with a new product.
1
Wash hands with a suitable antibacterial soap.
2
Prepare at least two gallons of a warm (45-60 °C 120-
140 °F) sanitizing solution (100 PPM available chlorine
concentration or 1 spoon of sodium hypoclorite diluted with two
litres of water) according to your local Health Codes and
manufacturer's specifications.
3
Place the parts in the sanitizing solution for five minutes.
4
Do not immerse the lighted top covers in liquid. Carefully
wash their undersides with the sanitizing solution.
5
Place the sanitized parts on a clean dry surface to air dry.
6
Wipe clean all exterior surfaces of the unit. Do not use
abrasive cleaner.
7. 3. 4 ASSEMBLY
1
Slide the drip tray into place.
2
Pinch tube faucet: push the dispensing handle (1) and
insert the pinch tube into its vertical seat in the bowl bottom(2).
Lightly pull the pinch tube end downwards til itl is well arranged
(3) (see figure 5).
11