3
Gravity faucet: install the faucet handle and the piston with
its gasket (see figure 6).
IMPORTANT
Insert the piston into its housing, taking care to accom-
pany it to the end so as to prevent it from damaging the
sharp edge around the hole. (see figure 7)
4
Fit the bowl gasket to the evaporator. Note: the largest brim
of the gasket must face against the drip plate (see figure 8).
5
Place bowl on the unit. Wet the gasket for ease of insertion.
Please take care that the hook on the backside of the bowl be
inserted properly in its seat on the upper drip plate.
(see figure 9).
figure 6
figure 7
figure 8
figure 9
6
Use fresh product to chase any remaining sanitizer from the
bowl(s). Drain this solution. Do not rinse out the machine.

7. 4 IN-PLACE SANITIZATION

The In-Place Sanitization prior to starting the machine may
be performed, if needed, only as further precaution, in
addition to the Disassembled Parts Sanitization described
before, but never in lieu of it.
1
Prepare two gallons of a warm (45-60°C, 120-140 °F)
sanitizing solution (100 PPM chlorine residual) according to
your local Health Codes and manufacturer's specifications.
2
Pour the solution into the bowl(s).
3
Using a brush suitable for the purpose, wipe the solution on
all surfaces protruding above the solution-level and on the
underside of the top cover(s).
4
Install the top cover(s) and operate the unit. Allow the
solution to agitate for about two minutes. Drain the solution out
of the bowl(s).
5
Use fresh product to chase any remaining sanitizer from the
bowl(s). Drain this solution. Do not rinse out the machine.

8 ROUTINE MAINTENANCE

Daily: inspect the machine for signs of product leaks past seals
and gaskets. If proper assembly does not stop leaks around
seals or gaskets, check for improper lubrication, worn or
damaged parts. Replace parts as needed with original spare
parts from the supplier.
IMPORTANT
Use gloves of a minimum PL 0-4 class (EN388).
8. 1 MAINTENANCE (TO BE CARRIED
OUT BY QUALIFIED SERVICE
PERSONNEL ONLY)
Montly: clean all internal components, primarily the condenser,
using compressed air, in order to remove dust.
To clean these internal parts, unplug the unit.
Condenser fins are very sharp. Use extreme caution when
cleaning.
ATTENTION
Verify the correct position of the cable before closing the
cabinet and before supplying electricity.
12