Phase
MODEL NAME
and fre-
quency
DZ17VSA181AA
DZ17VSA241AA
DZ17VSA301AA
1 Phase
DZ17VSA361AA
60Hz
DZ17VSA421AA
DZ17VSA481AA
DZ17VSA601AA
l
V
c
ow
oltage
onnectIonS
The unit is designed to work as part of a fully communicat-
ing HVAC system, utilizing a Daikin approved communicat-
ing thermostat, Communicating indoor unit, and up to four
wires. Route control wires through the low voltage port and
terminate in accordance with the wiring diagram provided
inside the top plate.
<1.5 - 3.0 ton>
Voltage Ports
MOP
MCA
(Max.
(Min.
overcur-
Voltage
circuit
rent
amp.)
protective
device)
12.7 A
15 A
17.4 A
20 A
22.7 A
25 A
208/230V
22.7 A
25 A
34.5 A
35 A
34.5 A
35 A
36.5 A
40 A
Tie high voltage wire with
clamp material (accessory)
LOW
HIGH
VOLTAGE
VOLTAGE
<3.5 - 5.0 ton>
Transmis-
sion line
selection
SHIELDING PLATE
18 AWG
(typical)
LOW
VOLTAGE
WIRE
noTE: The communicating thermostat is able to search and
identify the indoor and outdoor units when power is applied to
the system. Refer to the communicating thermostat's instal-
lation instruction manual for more information.
Connect low voltage communication wires (1, 2) to low volt-
age pigtail provided.
c
ommunIcatIon
noTE: A removable plug connector is provided with the
control board to make thermostat wire connections. This plug
may be removed, wire connections made to the plug, and
replaced. Do not connect multiple wires into a single terminal.
Typical 18 AWG wire may be used to wire the system compo-
nents. However, communications reliability may be improved
by using a high quality, shielded, twisted pair cable for the
data transmission lines.
t
-W
o
Wo
Ire
Low voltage wiring consists of two wires between the indoor
unit and heat pump and four wires between the indoor unit
and thermostat. The required wires are data lines 1 and 2,
"R" (24 VAC hot) and "C" (24 VAC common).
Never connect the power wiring to communication terminal.
(1, 2, R, C)
<In case of Air Handler>
1
125 ft.(*)
1
250 ft.(*)
1
(*) Allowable Maximum Length
14
14
Tie high voltage wire and
ground wire with clamp
material (accessory)
Voltage Ports
W
IrIng
, f
-W
I
utdoor
our
Ire
ndoor
Communicating Thermostat
2
C R
Air Handler Blower Integrated
2
R C
Control Module
Heat Pump Integrated
2
R C
Control Module
System Wiring
INSULATION
TUBE
(accessory)
GROUND
WIRE
HIGH
VOLTAGE
WIRE
W
IrIng