SUBMENU ITEM
CL Reset
Cool Airflow Trim Hi
*
1
Cool Airflow Trim Int
Cool Airflow Trim Low
Cool Airflow Profile
Cool ON Delay
Cool OFF Delay
Dehumidification Select
SUBMENU ITEM
Maximum Compressor RPS Range
for Cooling
(COOL RPS RANGE)
Maximum Compressor RPS Selec-
tion for Cooling
(COOL RPS SELECT)
SUBMENU ITEM
HT Reset
Heat Airflow Trim Hi
Heat Airflow Trim Int
Heat Airflow Trim Low
Heat ON Delay
Heat OFF Delay
Maximum Defrost Interval
SUBMENU ITEM
Maximum Compressor RPS Range
for Heating
(HEAT RPS RANGE)
Maximum Compressor RPS Selec-
tion for Heating
(HEAT RPS SELECT)
*
Depending on the connected Indoor unit, there are restrictions on the positive side Trim setting.
1
If you want to change the Cool Airflow Trim to positive side, be sure to confirm the Airflow Trim restrictions in the latest Indoor unit Installation Manual.
The latest Manual can be obtained from the website "DAIKIN CITY (Installation Manual/Unitary Split System)" or "PartnerLink (Info-
FinderPlus/Literature)".
[DAIKIN CITY URL]
https://www.daikincity.com/Library/
[PartnerLink URL]
https://partnerlinkmarketing.goodmanmfg.com/goodman/info-finder-plus
cool SETUP
USER MODIFIABLE OPTIONS
YES or NO
-15% to +15% in 3% increments
-15% to +15% in 3% increments
-15% to +15% in 3% increments
A, B, C, or D
5, 10, 20, 30 seconds
30, 60, 90, 120 seconds
ON or OFF
SET coolinG rUn VAlUES (cl rUn VAlUES)
USER MODIFIABLE OPTIONS
Five different compressor RPS
ranges will be provided.
10 compressor RPS values will be
provided within the range selected
in the COOL RPS RANGE menu.
HEAT SETUP
USER MODIFIABLE OPTIONS
YES or NO
-15% to +15% in 3% increments
-15% to +15% in 3% increments
-15% to +15% in 3% increments
5, 10, 15 seconds
30, 50, 70, 90 seconds
30 mins., 1 hr., 1.5 hrs. & 2 hrs.
SET HEATinG rUn VAlUES (HT rUn VAlUES)
USER MODIFIABLE OPTIONS
Five different compressor RPS
ranges will be provided.
10 compressor RPS values will be
provided within the range selected
in the HEAT RPS RANGE menu.
60
60
COMMENTS
Selecting to default factory setting.
Selects the cooling airflow trim amount.
Selects the cooling airflow trim amount.
Selects the cooling airflow trim amount.
Selects the cooling airflow profile.
Selects the indoor blower ON delay.
Selects the indoor blower OFF delay.
Selecting "OFF" disables dehumidification; selecting
"ON" enables dehumidification.
COMMENTS
Select the appropriate range for the installed system
configuration.
Select the appropriate compressor RPS for the
installed system configuration.
COMMENTS
Selecting to default factory setting.
Selects the Heating airflow trim amount.
Selects the Heating airflow trim amount.
Selects the Heating airflow trim amount.
Selects the indoor blower ON delay.
Selects the indoor blower OFF delay.
Selects time defrost interval
COMMENTS
Select the appropriate range for the installed system
configuration.
Select the appropriate compressor RPS for the
installed system configuration.