Filter Removal, Inspection And Replacement; Lubrication; Storage; Maintenance Schedule - RIDGID OL50135AL Manual Del Operador

Ocultar thumbs Ver también para OL50135AL:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Filter Removal, Inspection and Replacement

To change a filter, remove the pump/ motor shroud to expose pump. If filter is dirty,
replace.

Lubrication

Before plugging in compressor, make sure
the crankcase is filled with 250ml/ 8.4 oz. of
ISO 100 (SAE 30), non-detergent
compressor oil, or Mobil 1 5W30 synthetic.
Use dipstick to check oil-level.
To Drain and replace the oil:
- Place a suitable container underneath
the drain to collect used oil.
- Remove oil drain plug with a 4mm hex
wrench.
- When the used oil has drained, reinstall
the drain plug and tighten using the 4mm
hex wrench.
- Remove the dipstick
- Add 250ml/ 8.4 oz. of ISO 100 (SAE 30),
non-detergent compressor oil, or Mobil 1
5W30 synthetic.
NOTE: Avoid overfilling with oil. Make sure
to check that the oil level is not above MAX
line on the dipstick.
- Re-insert the dipstick.

Storage

1. When not in use, compressor should be
stored in a cool dry place.
2. Tank should be drained of moisture.

Maintenance Schedule

Operation
Check Oil Level
Drain Tank
Check Air Filter
Check Safety Valve
Blow Dirt From Inside Motor
Change Oil
Oil fill
hole
Drain
Plug
3. Hose should be disconnected and hung
open ends down to allow any moisture
to drain.
Daily
Weekly
Every 3 Months
G
G
G
G
G