5.4
Operating position
The burner is designed to operate only in the po-
sitions 1, 2, 3 and 4.
Installation 1 is preferable, as it is the only one that
WARNING
allows the maintenance operations as described
in this manual.
The installations 2, 3 and 4 permit operation but
make maintenance and inspection of the combus-
tion head more difficult, pag. 27.
1
D4618
5.5
Boiler fixing
7
8
20094184
Installation
2
6
1
Fig. 5
5
1
10
Any other positioning could compromise the cor-
rect operation of the appliance.
The installation 5 is prohibited for safety reasons.
WARNING
3
4
Fix the bolt (6) and nut (7) onto the flange (1) as in Fig. 5.
Fix the flange (1) to the appliance (4) using the supplied nuts
(3) with the gasket (5) inbetween as in Fig. 6.
Insert the burner tube through the flange and push to ensure
full insertion. With the burner collar fully inserted into the
flange the O-ring will form a seal.
Fix the securing nut (8)(Fig. 6) onto the bolt (6).
The seal between burner and boiler must be
airtight.
WARNING
3
4
GB
5
Fig. 4
Fig. 6