Preliminary Checks; Operating Position - Riello RS5D Instrucciones De Instalación, Uso Y Mantenimiento

Quemadores de gas con aire soplado
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5.4

Preliminary checks

Control of the supply
After removing all the packaging, check the integ-
rity of the contents.
In the event of doubt, do not use the burner; con-
CAUTION
tact the supplier.
The packaging elements (cardboard box, clips,
plastic bags, etc.) must not be abandoned as they
are potential sources of danger and pollution; they
should be collected and disposed of in the appro-
priate places.
Control of burner characteristics
Check the identification label of the burner (Fig. 6), showing:
A
the burner model;
B
the burner type;
C
the cryptographic year of manufacture;
D
the serial number;
E
the data for electrical supply and the protection level;
F
the electrical power consumption;
G
the data of the burner's minimum and maximum output pos-
sibilities (see Firing rate)
Warning. The burner output must be within the boiler's firing
rate.
5.5

Operating position

 The burner is set up to operate only in posi-
tions 1, 2, 3, 5, 6 and 7 (Fig. 7).
 Installation 1 is preferable, as it is the only
one that allows the maintenance operations
WARNING
as described in this manual.
 The installation layout illustrated in position 5
is only possible using the "MULTI-BLOC rota-
tion kit", to be ordered separately.
20141174
1
2
5
6
Installation
The figure of the label (Fig. 6) is indicative.
Some of the data may be arranged in a different
position.
WARNING
R.B.L.
II2ELL 3B/P DE
II2H3B/P
II2H3 GB,IE,IT
AT,CH,IS
N2L3B/P LU
I2E(P)B.I3 BE
Icc
II2L3B/P NL
Imax
II2Er3P FR
20098188
A burner label that has been tampered with, re-
moved or is missing, along with anything else that
prevents the definite identification of the burner
makes any installation or maintenance work diffi-
WARNING
cult.
 Any other position could compromise the cor-
 Installation 4 are forbidden for safety rea-
DANGER
3
7
14
GB
TIPO TYP
A
TYPE
D
E
FAM.2
GAS
FAM.3
GAZ
A
RIELLO S.p.A.
PESO
kg
I-37048 Legnago (VR)
A
rect operation of the appliance.
sons.
4
D4450
B
B
C
F
G
Fig. 6
Fig. 7