2.
Select Intensity on the left column to display a list of Intensity function
sub-categories.
3.
Select Strobe as the desired function. The window will close and you
will see Strobe assigned as the function for channel 10. Note the feature
column will auto-fill with 'Shutter'.
4.
Select the DMX value cell for this DMX Entry and press
DMX value for the Open Shutter according to the DMX protocol (0)
and press
5.
Select the Real World value cell for this DMX Entry and press
dialog box will display a list of shutter options. Select the 'open' shutter
option and press
6.
Repeat the above steps for the 'closed' shutter ability of the fixture.
7.
Select the function cell for a blank DMX Entry of channel 10 and press
Set
8.
Select Intensity on the left column to display a list of Intensity function
sub-categories.
9.
Select Strobe as the desired function. The window will close and you
will see Strobe assigned as the function for channel 10. Note the feature
column will auto-fill with 'Shutter'. Select this cell and press
Choose Rate from the dialog box.
10. Select the DMX value cell for this DMX Entry and press
DMX range for the Linear Strobe according to the DMX protocol (1>127)
and press
11. Select the Real World value cell for this DMX Entry and press
the Real World value to be displayed in Hertz (0>30hz) and press
12. Repeat steps 8-13 for the random strobe ability of the fixture.
Fixture Control commands from Strobe channel:
1.
Select the function cell for a blank DMX Entry of channel 10 and press
Set
2.
Select Control on the left column to display a list of Control function
sub-categories.
3.
Select Fixture Control as the desired function. The window will close
and you will see Fixture Control assigned as the function for channel
10. Note the feature column will auto-fill with 'Idle'. Select this cell and
press
4.
Select the DMX value cell for this DMX Entry and press
DMX for the fixture reset according to the DMX protocol (205) and
press
5.
Repeat the above steps for the shutdown ability of the fixture.
Note that Real World values are not allowed for Control functions.
354
.
Enter
.
Enter
. A dialog will appear with a list of function categories.
.
Enter
. A dialog will appear with a list of function categories.
. Choose Global Reset from the dialog box.
Set
.
Enter
Capítulo 31: El Creador de Aparatos (Fixture Builder)
. Enter the
Set
. A
Set
.
Set
. Enter the
Set
. Enter
Set
.
Enter
. Enter the
Set
Flying Pig Systems

Publicidad

Tabla de contenido
loading

Productos relacionados para High End Systems Wholehog III