03. MODULE IP CONNECTIONS IDENTIFICATION

1.
P4 connector (2.1mm - positive internal) for external power supply.
2.
CR2032 3V battery to keep the internal clock.
3.
Molex 5-way connector, RS232 for communication with PC.
4.
Digital input for generating an emergency event.
5.
Polarized connector with Wiegand input and 2 x RS485 - Water shor-
tage alarm and Biometrics.
6.
CAN 1 and CAN 2 connection for communication with receivers (in-
ternal 100R resistor).
7.
RJ-45 – Ethernet connector (TCP/IP and UDP).
8.
Input slot for Internal Micro SD Card, for automatic backup and data
restoration.
9.
P2 connector for amplified speakers (optional accessory).
10.
USB HOST port (for computer keyboard, USB flash drive for backup/
restore, firmware update).
11.
Button for forced firmware update.
12.
Connection for basic biometrics module, LN3000

03.1 INTERIOR OF THE PCI BOARD EQUIPMENT

1
POWER SUPPLY
P4 - 12 VDC/1A
2
3V CR2032
BATTERY
6
[figure 3.1.a, figure 3.2.a and figure 3.2.b]
12
BIOMETRIC
MODULE LN3000
3
SERIAL RS-232
4
DIGITAL INPUT
1. 5 VDC OUTPUT
2. 3,3 VDC OUTPUT
1. GND
3. GND
2. EMERGENCY
4. TX
3. NOT IMPLEMENTED
5. RX
11
FORCED
BOOTLOADER
5
WIEGAND READERS
INPUT
RS485 1 - TERMINAL BLOCK
RS485 2 - BIOMETRICS
1. 12VDC OUTPUT
2. GND
CAN 1
3. WIEGAND D0
1. CAN H
4. WIEGAND D1
2. CAN L
5. RS485-1 A+
6. RS485-1 B-
CAN 2
7. RS485-2 A+
3. CAN H
8. RS485-2 B-
4. CAN L
Figure 3.1.a
- ENGLISH -
209
10
USB PORT
FLASH DRIVE/
KEYBOARD
VOICE OUTPUT
8
AUXILIARY
SD CARD
7
6
NETWORK TCP/IP
10/100 BASE-T
9
P2
SPEAKER