Site Preparation

Electrical Requirements

Installation must comply with all applicable electrical codes.
The electrical supply should be located within the shaded
area shown in the illustration below. A separate circuit ser-
vicing only this appliance is required. A ground fault circuit
interrupter (GFCI) is not recommended and may cause
interruption of operation.
The electrical outlet must be positioned with the ground-
ing prong to the right of the thinner blades.
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
Receptacle
RIGHT SIDE
OF OPENING
9"
3"
(229)
(76)
4"
(102)
FLOOR
1
/
"
4
(6)
Electrical supply location
6 | Sub-Zero Customer Care 800.222.7820
115 VAC, 60 Hz
15 amp dedicated circuit
3-prong grounding-type
CAUTION
The outlet must be checked by a qualified electrician
to be sure it is wired with the correct polarity. Verify
the outlet is properly grounded.
WARNING
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly quali-
fied persons in order to avoid a hazard.
WARNING
Do not locate multiple portable socket-outlets,
power strip, or portable power supplies at the rear of
the appliance.
WARNING
Do not use an extension cord, two-prong adapter, or
remove the power cord ground prong.