1st case: no existing configuration (system cable HG5621)
• If necessary, install the seal for Sub-D 25-pin connector (Plate A-V, item 2) on the 25-pin
connector for system cable HG5621 to ensure a IP54 level seal
• Connect the system cable to the BER
• On the back panel of the TM-CU (Plate A-IV):
- Connect the system cable HIROSE connector (item 11) to the 22-pin male system
connector linking it to the terminal
- Insert the system cable into its recess (item 10)
- Insert the rubber retaining piece into its recess (item 9)
2nd case: with a CCP configuration (system cable HG4354)
• Connect the Sub-D 25-pin male connector of the adapter cable HG5619 to the Sub-D
25-pin female connector of the system cable HG4354 in place
• On the back panel of the TM-CU:
- Connect the HIROSE connector (DF series, 11-22-pin female connector) of the
adapter cable (item 11) to the 22-pin male system connector of the TM-CU
- Insert the adapter cable into its recess (item 10)
- Insert the rubber retaining piece into its recess (item 9)
3rd case: with a CH configuration (system cable HG5114)
• Connect the Sub-D 25-pin male connector of the HG5620 adapter cable to the Sub-D
25-pin female connector of the system cable HG5114 in place
• On the back panel of the TM-CU:
- Connect the HIROSE (DF series, 11-22-pin female connector) connector of the
adapter cable (item 11) to the 22-pin male system connector of the TM-CU
- Insert the adapter cable into its recess (item 10)
- Insert the rubber retaining piece into its recess (item 9)
5.2.3
Installing the TM-CU on the pivot
1st case: installing the TM-CU in the dashboard shell
• Install and secure the cable support plate (item 3) to the back panel of the TM-CU with
two butterfly screws (item 5)
• Install the dashboard seal (item 7) on the dashboard shell (item 4), paying attention to
the order of assembly. The seal tab "L" (Left) must be positioned on the left.
• Carefully insert the TM-CU (item 2) in the dashboard shell (item 4)
• Secure the TM-CU (item 2) inside the dashboard shell (item 4) with the two fastening
screws (item 20)
2nd case: installing the TM-CU on the support plate
• Carefully position the back face of the TM-CU (item 2) on the cable support plate
(item 3)
• Secure the cable support plate (item 3) with two butterfly screws (item 5)
This document and its contents are the property of Airbus DS SLC and must not be copied or circulated without authorisation.
Any usage outside the subject expressly specified is prohibited. Copyright
IH - PS11760AQLAB01
TETRAPOL Mobile - Control Unit - Hardware Installation Handbook
(PlateA-I)
©
2015 - 2019 - Airbus DS SLC - All rights reserved.
08/2019