Important Safety Instructions

SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed
during the installation, operation, maintenance and storage of the UPS and
batteries. Failure to heed these warnings may affect the warranty.

UPS Location Warnings

• Install your UPS within an enclosure or location that protects against excessive
moisture, conductive contaminants, dust or direct sunlight.
• For best UPS performance, maintain site temperature between -40ºF and 176ºF
(-40ºC and 80ºC).
• Leave adequate space around all sides of the UPS for proper ventilation.
• Only set the UPS upright on a sturdy flat surface. Do not block fans or ventilation
holes, as this will seriously inhibit the unit's internal cooling and cause product
damage not covered under warranty.

UPS Connection Warnings

• Hardwire the UPS directly to a properly grounded power source.
• If the UPS receives power from a motor-powered AC generator, the generator must
provide clean, filtered, computer-grade output.
• The mains power that supplies power to the UPS should be easily accessible and
located near the UPS.

Equipment Connection Warnings

Install in accordance with National Electrical Code standards ANSI/
NFPA 70 and Canadian Electrical Code, Part I, C22.1.
Short-circuit backup protection and overcurrent protection is provided
by the building installation.
To reduce the risk of fire, connect only to a circuit provided with
branch circuit overcurrent protection in accordance with the National
Electrical Code, ANSI/NFPA 70 and the Canadian Electrical Code,
Part I, C22.1. Be sure to provide a disconnect device in the end use
installation.
• Use of this equipment in life support applications where failure of this equipment
can reasonably be expected to cause the failure of the life support equipment or to
significantly affect its safety or effectiveness is not recommended.
• Do not connect surge protectors or extension cords to the output of your UPS. This
might damage the UPS and may affect the surge protector and UPS warranties.