Bosch Rexroth LT303 Manual Del Usuario página 12

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
12/40 Bosch Rexroth AG | Electric Drives and Controls
4 Assembly Instructions
Number of
LT303
channels
with
in BT300
EC302
1 -3
all combinations admissible
4
4*
3*
1*
2*
0
1
2
5
5*
4
3
2
1
0
0
0
3
2
1
Table 2:
*
within this line all combinations are
admissible
0
not assembled
Formula for determining the number n
n
, n
of tightening channels:
4
5
× 7 A (EC302)
n
2
×14 A (EC303)
+ n
3
×28 A (EC304)
+ n
4
×45 A (EC305)
+ n
5
≤ 145 A
: Number of tightening channels
n
2
of size 2 (EC302)
: Number of tightening channels
n
3
of size 3 (EC303)
: Number of tightening channels
n
4
of size 4 (EC304)
: Number of tightening channels
n
5
of size 5 (EC305)
LT303
LT304
LT305
with
with
with
EC303
EC304
EC305
4*
0
3*
0
1
1*
2
1
2*
1
1
0
3
1
0
1
2
0
0
2
5*
5*
0
0
0
1
1*
1*
1
2*
2*
1
3*
3*
1
4
0
1
3
1
1
2
2
1
0
0
2
1*
1*
2
2
0
2
, n
,
2
3
LT30x | 3 609 929 719/1.2
In addition, it is also possible to use a free
SE/LT-Slot for a KE300.
For safety reasons, unoccupied card-slots
must be closed off with BP 301 dummy pa-
nels, order no. 3 608 871 391. Slots, which
are not closed off, can cause electromagne-
tic disruptions in the system.
When the system is switched on, the servo
amplifier recognizes the size of the spindle. If
the combination is not permitted, a respecti-
ve error message is sent to the tightening
control unit. In such cases, it is not possible
to start the tightening process.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rexroth lt304Rexroth lt305

Tabla de contenido