Operation DC Green System
Start and stop
The unit is started and stopped manually on the
display, see below: As an alternative to manual
starting, the outlets can be equipped with micros-
witches/pressure switches. If no outlet is open, the
unit will continue to run for 5 mins, before shut-
ting down. The run-on time can be adjusted, see
below.
The system can also be confi gured for timer
control. This means that starting and stopping are
controlled by a programmed timer. This operation
is usually performed after a work shift, when the
system shuts down and cleans the fi lter during
work breaks. For details of setting the timer, see
below.
Operation DC 11-Module
Filter cleaning (manual)
The fi lter should be cleaned 1-2 times per day when
running continuously.
1.
Start the machine.
2. Close the shutter valve on the machines inlet.
3. With slow, even motion open the pulse top by
lifting the handle. Repeat three to six times.
4. Open the shutter valve.
Emptying separated material
All separated material is collected under the cy-
clone in a plastic sack or container.
The plastic sack should be changed when the
dust level is about 5 cm under the outlet fl ap. The
plastic sack must be sealed after is has been taken
off the machine. Use only original plastic sacks.
2017-03-08
Note that if extraction equipment smaller than 38
is being used, the fl ap should be held open for a
short time before connecting the hose , so that
the system is able to switch to control mode. When
the equipment has a very small dimension, it may
occasionally be necessary to make a hole in the
hose connector or the hose to admit extra air. The
hole should be 15 - 20 mm.
The system can also be confi gured for fi lter clea-
ning during operation. In this case, the fi lters are
cleaned approximately once an hour, at a time
when the system is in energy-saving mode.
The container should be emptied when it is fi lled
to ca 3/4. Some containers have a sight glass so
the fi lllevel can be viewed from the outside. When
emptying the container you normally should put
a trolley or moveable load bearing item under the
container before the eccentric lock is released.
Alarm
When the alarm lamp is on the motor protection
has tripped. The fault should be investigated and
attended before the motor protection is restored
and the system can be started once again.
DC 11-Module - 42