Trouble Shooting
Problem
Filter cleaning does not fun-
ction.
The red alarm lamp is on.
Motor will not run.
The motor stops directly after
starting.
Motor runs but no suction.
Pump runs but poor suction.
Fault
Compressed air supply
broken.
Electric supply broken.
The motor protection has
tripped.
Electrical supply is not con-
nected.
Electrical power does not
reach the machine.
Electrical disconnect is
locked out.
Motor circuit breaker (Logo)
is in stop position.
Thermal overload tripped.
Incorrect fuse.
The thermal overload is
incorrectly set.
Suction tubing not connec-
ted.
Blocked tubing or hoses.
There is no plastic sack or
container attached to the
fi ler unit.
Fan rotation is backwards.
Drive belt broken.
Leakage in the ductwork.
DC 11-Module - 59
Solution
Check solenoid valves, hoses, con-
nection s and compressor.
Check solenoid valves, cables, con-
nections, fusing and transformer.
Investigate what is wrong and reset
the motor protection.
Connect.
A qualifi ed electrician should check
the supply.
Find the person responsible for the
lock out and check to see if the sys-
tem is clear for operation. Reverse
the lock out.
Switch on the circuit breaker.
If the thermal overload protection
of the turbo pump is tripped, the
fault must be located and corrected
before operating the system. There-
after, the indicator can be reset.
Change to correct fuse rating and
type.
Electrician should be called to
investigate.
Connect the tubing.
Clean.
Connect a plastic sack or a contai-
ner.
Electrician should take care of this.
Change.
Locate and repair.