Dustcontrol DC 11-Module Instrucciones Originales página 94

Ocultar thumbs Ver también para DC 11-Module:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 171
Fehlersuche DC Green System
Problem
Alarm codes
E.OHT
Other codes - see converter
manual
Bad suction in outlet
The rotation speed of the pump
oscillate upp and down.
2017-03-08
Fault
Thermowatch alarm
The fl ow sensor do not
notice the fl ow - the system
stands in the saving mode.
Adjusting
Natural vibration in the
system.
DC 11-Module - 94
Solution
Control the function of the fl ow
sensor. Change sensor if nec-
cessary.
Look in the sysem for leakage.
Tight.
Check if any suction equipment
has a smaller inlet than diameter
32 or very long hose. Then try
to make a 15-20 cm hole in the
hose sleeve.
Control the function of the fl ow
sensor. Change sensor if nec-
cessary.
Check if any suction equipment
has a smaller inlet than diameter
32 or very long hose. Then try
to make a 15-20 cm hole in the
hose sleeve.
A small variation is normal.
If the variation is strong, contact
Dustcontrol for trimming the
system.
Part No 94153-G

Publicidad

Tabla de contenido
loading

Tabla de contenido