Dustcontrol DC 11-Module Instrucciones Originales página 55

Ocultar thumbs Ver también para DC 11-Module:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 171
Service DC 11-Module
Changing the HEPA fi lter:
Remove top (pos10) of cyclone by disassemble
locking ring.
Remove old outlet. Assemble new outlet (pos28).
Connect outlet with Hose d110 artnr 2030 to inlet
of pump. Use joint artnr 3031 to secure Hose d110
artnr 2030 to outlet and inlet of pump.
Remove funnel from solenoidvalve with hook
wrench or plumber wrench. Assemble tube (pos1)
on solenoid valve. Assemble funnel on tube (pos1).
Assemble lower fi lter (pos8) on fi ne fi lter in cyclone.
Assemble upper fi lter (pos8) on HEPA module
(pos3).
Assemble HEPA module (pos3) on outlet module.
Lock everything with locking ring(pos9).
Fasten the eight MRT 6*50 screws (pos4) that will
tighten both fi lter(pos8). Inspect from inside of HE-
PAmodule (pos3) that the fi lters (pos8) are secured.
Use Thread sealant Loctite542 or similar for the
eight MRT 6*50 screws (pos4).
Assembly the top (pos10) on the HEPAmodule
(pos3).
Lock everything with locking ring(pos9).
Max Q= 1000 m3/h
Max dp= 40kPa
DC 11-Module - 55
Part No 94153-G

Publicidad