Dustcontrol DC 11-Module Instrucciones Originales página 49

Ocultar thumbs Ver también para DC 11-Module:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 171
Installation DC 11-Module
1
5
Connection points
1. Compressed air feed 4 l/s, 4 bar (for use with
automatic fi lter cleaning).
2. Electric feed (for use with integrated control
box).
3. Connection point for micro switch circuit(where
existing).
4. Connection of motor tension from a separate
control box (in some cases).
5. Inlet to cyclone (can be rotated for preferred
direction).
6
2
3
4
7
DC 11-Module - 49
6. Exhaust.
7. Holes for fi tting the unit to the ground (where
existing).
The unit can be mounted on concrete surface/
fl oor of suitable thickness.
The electrical connection should be connected
to adequate starting equipment. A certifi ed elec-
trician should make the installation. 5 pin Euro
connection is available as an alternative.
The equipment is prepared to draw 3-phase
electric feed and low volt cabling into its enclo-
sure.
Electric cables should be mounted to make it
possible to raise the unit 200 mm for potential
bearing changes; without that the electrical con-
nection would need to be disconnected.
A separate, lockable disconnect must be instal-
led where it is readily accessible to the pump.
Connect the pipe work to the inlet and possible
to the outlet. Never start the pump without the
correct cables and hoses being connected. If the
outlet is directed up it should be connected with
an exhaust diffuser, a bend or a fl ap so rainwater
and objects do not fall into the outlet. Exhaust
air can be between 100-150 o C.
Put the plastic bag under the cyclone or connect
the container.
Part No 94153-G

Publicidad

Tabla de contenido
loading

Tabla de contenido