Replacing Return Spring Of Switching Pedal - Bosch TCE 4460 Instrucciones De Reparacion

Ocultar thumbs Ver también para TCE 4460:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Fig. 5:
Inserting control pin
3.2
Replacing return spring of switching
pedal
1. Disconnect the power supply.
2. Remove the cover (A) next to the pedal for turning the
clamping flange.
3. Unscrew the pin (B) under the plastic pedal.
4. Pull out the pedal (C).
5. Unscrew the two bolts (D) attaching the switching
pedal assembly.
Fig. 6:
Removing cover
6. Remove the entire switching mechanism (E) from the
machine without disconnecting the cables.
7. Remove the bolt (F) holding the spring (G) in position
by way of the sleeve (H).
Robert Bosch GmbH
Replacement of components | TCE 4460-TCE 4465 | 41
Fig. 7:
Replacing spring
8. Insert the new spring in both openings (I).
9. Tension the spring by turning it through 180°. When
doing so hold the spring with the sleeve (H).
Fig. 8:
Turning spring to tension
10. Fit and tighten the bolt (F).
11. Re-insert the switching mechanism in the machine
and screw on.
12. Attach the pedal.
13. Attach the right cover.
14. Connect the power supply.
en
|
1 695 100 278