Tabella parametri di saldatura (set value)
14A
Processo
1,0 mm
1,5 mm
Materiale
Filo
Gas
S
U0
S
(m/min)
(V)
(m/min)
Fe
0,8
CO
2,5
19,0
4,5
19,5
2
Fe
1,0
CO
2,0
18,0
2,5
19,0
2
Fe
1,2
CO
1,0
18,0
2,0
20,0
2
14B
Processo
1,0 mm
1,5 mm
Materiale
Filo
Gas
S
U0
S
(m/min)
(V)
(m/min)
Fe
0,8
ArCO
3,0
16,0
6,0
18,0
2
Fe
1,0
ArCO
2,0
15,0
3,0
16,0
2
Fe
1,2
ArCO
1,5
16,5
2,5
17,5
2
Fe
1,6
ArCO
1,0
17,0
2
FeFlux
1,2
ArCO
2
CrNi
1,0
ArCO
3,0
15,0
4,0
16,0
2
CrNi
1,2
ArCO
2,0
15,0
3,0
16,0
2
AI
1,0
Ar
4,0
14,5
6,0
15,0
AI
1,2
Ar
3,5
13,0
5,0
15,0
Tabella 1
2,0 mm
3,0 mm
4,0 mm
U0
S
U0
S
U0
S
U0
(V)
(m/min)
(V)
(m/min)
(V)
(m/min)
(V)
(m/min)
7,0
21,0
11,0
27,0
13,0
29,0
18,0
3,0
20,0
4,5
21,0
6,0
22,5
9,0
2,5
21,0
3,5
22,0
4,5
23,0
7,5
2,0 mm
3,0 mm
4,0 mm
U0
S
U0
S
U0
S
U0
(V)
(m/min)
(V)
(m/min)
(V)
(m/min)
(V)
(m/min)
7,5
19,5
11,0
20,0
14,0
26,0
18,0
4,0
17,0
6,0
19,0
8,0
20,0
11,5
3,5
18,0
4,5
20,5
5,5
20,5
8,0
2,0
18,0
2,5
18,5
3,0
19,5
4,0
6,0
21,0
8,0
6,0
17,0
8,5
20,0
9,0
25,0
10,0
3,5
16,5
6,0
18,0
8,0
24,0
10,0
7,5
16,0
9,0
19,0
11,0
22,0
13,0
8,0
16,0
9,0
17,0
10,0
18,0
13,0
Regolazione del processo di saldatura
Tenere premuta la manopola (11A) per aprire il menù dei parametri secondari.
Selezionare il parametro girando la manopola (10) e regolarlo girando la manopola (11).
Per chiudere il menù premere brevemente (11A). Premere per breve tempo (12) per attivare la
visualizzazione di Fxx (F = function) nomi parametri on/off.
6,0 mm
10,0 mm
Parametri MIG/MAG
S
U0
S
U0
(V)
(m/min)
(V)
30,0
24,0
37,0
A
24,5
14,0
32,0
28,5
11,0
36,0
m/min
t1
S
6,0 mm
10,0 mm
S
U0
S
U0
(V)
(m/min)
(V)
GS.F / F22 (gas flow) 0,5-27 l/min (solo macchine con IGC) (kit opzionale)
31,0
24,0
33,0
26,5
16,0
30,0
29,0
10,0
32,0
22,0
5,5
29,0
Parametri MMA
25,0
11,0
28,0
Quando si sia impostato il programma MMA
27,0
sono selezionabili solo i seguenti parametri :
24,0
12,0
31,0
A
25,0
15,0
27,0
23,0
15,0
26,0
t
Figura 1
SIGMA SELECT BASIC
Corrente di saldatura (A)
Pr.G / F31 Pre-gas
S.St / F32 Soft start
Po.G / F38 Post-gas
SP.t / F39 Tempo puntatura/Spot time (0,0 sec.)
t2
S
S
HS.A / F11 Hotstart
HS.t / F12 Tempo di Hotstart (0,5 sec.)
Arc / F13
Arc power
Corto circuito
Corrente di
t
saldatura (A)
GUIDA RAPIDA
(0,2 sec.)
(1,0 m/min.)
(3,0 sec.)
t
(25%)
(25%)
IT 50113805 A