CR1000/CR1250

11 Disassembly

DANGER
Risk of injury due to unexpected start-up
The following instructions must be adhered to during all maintenance, servicing, assembly, disassembly and repair work:
• Switch off the power source.
• Disconnect all electrical connections.
NOTICE
• Only qualified personnel are permitted to perform work on the device or system.
• Please also consult the operating instructions for the welding components and welding torch.
• Observe the information provided in the following section:
 8 Putting out of operation on page EN-13.
DANGER
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed or worn parts.

12 Disposal

When disposing of the system, local regulations, laws, provisions, standards and guidelines must be observed. Observe the
regulations on the disposal of electronic scrap and dispose of it at your local waste disposal site (e.g. recycling centre).
To correctly dispose of the product, it must first be disassembled. Please take note of the following information:
 11 Disassembly on page EN-17
BTC coolants:
The coolant must not be disposed of with normal household waste. Do not allow the product to enter the sewage system.
Please take note of the following information in the safety data sheet:
 Section 13 Disposal considerations
• 14 06 03*: other solvents and solvent mixtures
• 15 01 10*: Packaging that contains residues of dangerous materials or has been soiled by dangerous materials
• 15 01 02: Plastic packaging
Contaminated packaging:
Recommendation: Disposal in accordance with official regulations.
Recommended cleaning agents: water, if necessary with added cleansing agents.
12.1 Materials
This product is mainly made of metallic materials, which can be melted in steel and iron works and are thus almost infinitely
recyclable. The plastic materials used are labelled in preparation for their sorting and separation for later recycling.
12.2 Consumables
Oil, greases and cleaning agents must not contaminate the ground or enter the sewage system. These substances must be
stored, transported and disposed of in suitable containers. Please observe the relevant local regulations and disposal
instructions in the safety data sheets specified by the manufacturer of the consumables. Contaminated cleaning tools
(brushes, rags, etc.) must also be disposed of in accordance with the information provided by the consumables'
manufacturer.
12.3 Packaging
ABICOR BINZEL has reduced the transport packaging to the necessary minimum. The ability to recycle packaging
materials is always considered during their selection.