Installation to Concrete Ceilings or Concrete/Cinder Block Walls
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete
thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid
part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifica-
tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to
avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all at-
tached hardware and components.
NOTE: Wall installation with models PPC, PPC-S
2
and PPC-W is not available.
Place ceiling/wall plate (A) on ceiling or wall as a
template. Note: Place ceiling/wall plate according
to position of opening in outer channel (B) as shown
in figure 2.4. or figure 2.5. Drill two 1/4" (6 mm) dia.
holes to a minimum depth of 2.5" (64 mm). Attach
ceiling/wall plate using two concrete anchors (I), two
washers (W) and two #14 x 2.5" wood screws (H)
as shown in figure 2.6. Tighten wood screws until
ceiling/wall plate is firmly attached.
WARNING
• Tighten wood screws firmly, but do not overtighten.
Overtightening can damage the screws, greatly
reducing their holding power.
• Never tighten in excess of 80 in • lb (9 N.M.).
WARNING
• Always attach concrete expansion anchors directly
to load-bearing concrete.
• Never attach concrete expansion anchors to con-
crete covered with plaster, drywall, or other finishing
material. If mounting to concrete surfaces covered
with a finishing surface is unavoidable, the finishing
surface must be counterbored as shown below. Be
sure concrete anchors do not pull away from con-
crete when tightening screws. If plaster/drywall is
thicker than 5/8" (16 mm), custom fasteners must be
supplied by installer (not UL approved).
INCORRECT
A
concrete
plaster/
dry wall
Visit the Peerless Web Site at www.peerlessmounts.com
WARNING
CORRECT
A
concrete
plaster/
dry wall
6 of 33
CEILING
INSTALLATION
fig. 2.4
CONCRETE
CEILINg
OPENINg ON OUTER
CHANNEL (B) INDICATES
FRONT OF MOUNT
WALL INSTALLATION
(ExCEPT FOR
PPC MODELS)
CONCRETE
WALL
fig. 2.5
OPEnIng On
OUTER CHANNEL (B)
INDICATES TOP OF
MOUNT
B
fig.
1
2.6
Drill holes and insert anchors (I).
2
Place plate (A) over anchors (I) and secure with washers (W)
and screws (H).
3
Tighten all fasteners.
For customer care call 1-800-865-2112 or 708-865-8870.
H
B
A
I
H
W
concrete
surface
A
H
W
ISSUED: 12-26-07 SHEET #: 055-9494-1
I
A
W
CINDER
BLOCk
WALL
I
I