In case of damage and improper use of the battery, va-
u
pours may be emitted. The battery can set alight or ex-
plode. Ensure the area is well ventilated and seek medical
attention should you experience any adverse effects. The
vapours may irritate the respiratory system.
If used incorrectly or if the battery is damaged, flam-
u
mable liquid may be ejected from the battery. Contact
with this liquid should be avoided. If contact accident-
ally occurs, rinse off with water. If the liquid comes
into contact with your eyes, seek additional medical
attention. Liquid ejected from the battery may cause ir-
ritation or burns.
The battery can be damaged by pointed objects such
u
as nails or screwdrivers or by force applied externally.
An internal short circuit may occur, causing the battery to
burn, smoke, explode or overheat.
When the battery is not in use, keep it away from pa-
u
per clips, coins, keys, nails, screws or other small
metal objects that could make a connection from one
terminal to another. A short circuit between the battery
terminals may cause burns or a fire.
Only use the battery with products from the manufac-
u
turer. This is the only way in which you can protect the
battery against dangerous overload.
Only charge the batteries using chargers recommen-
u
ded by the manufacturer. A charger that is suitable for
one type of battery may pose a fire risk when used with a
different battery.
Protect the battery against heat, e.g. against
continuous intense sunlight, fire, dirt, water
and moisture. There is a risk of explosion and
short-circuiting.
Remove the rechargeable battery/non-rechargeable
u
batteries from the measuring tool before carrying out
work on the measuring tool (e.g. assembly, mainten-
ance, etc.). The battery/batteries should also be re-
moved for transport and storage. There is risk of injury
from unintentionally pressing the on/off switch.
Caution! When using the measuring tool with
u
Bluetooth®, a fault may occur in other devices and sys-
tems, aeroplanes and medical devices (e.g. pace-
makers, hearing aids). Also, damage to people and an-
imals in the immediate vicinity cannot be completely
excluded. Do not use the measuring tool with
Bluetooth® in the vicinity of medical devices, petrol
stations, chemical plants, areas with a potentially ex-
plosive atmosphere and in blasting areas. Do not use
the measuring tool with Bluetooth® on aeroplanes.
Avoid using the product near your body for extended
periods.
The Bluetooth® word mark and logos are registered trade-
marks owned by Bluetooth SIG, Inc. and any use of such
marks by Robert Bosch Power Tools GmbH is under li-
cense.
Protect the measuring tool, particularly the area
u
around the air humidity, ambient temperature and in-
Bosch Power Tools
frared sensor, from moisture, snow, dust and dirt. The
reception lens could fog up or become contaminated
and distort the measurements. Incorrect settings on the
tool and other atmospheric influences may make the
measurements inaccurate. Object temperatures could be
shown to be hotter or colder than they are, which may
present a danger if touched.
Correct temperature measurements are only possible
u
if the set emissivity and emissivity of the object
agree, and the correct reflected temperature is set.
Otherwise, object temperatures could be shown to be
hotter or colder than they are, which may present a
danger if touched.
Safety Instructions When Using Thermocouples
Thermocouples must not be used in live electrical sys-
u
tems. This poses a risk to life!
Using a thermocouple means contact with the object
u
measured. Therefore, watch out for potential dangers
due to temperature, voltage or a chemical reaction.
Product Description and
Specifications
Please observe the illustrations at the beginning of this oper-
ating manual.

Intended Use

The measuring tool is intended for contactless measurement
of surface temperature, ambient temperature and relative
humidity. It calculates the dew point temperature and indic-
ates thermal bridges and mould risk. Mould spores cannot
be detected with the measuring tool. However, it can help to
detect conditions early on that can encourage mould growth.
The measuring tool may not be used to measure the body
temperature of humans or animals or for other medical pur-
poses.
The measuring tool is not suitable for measuring the surface
temperature of gases.
Temperature measurement in liquids is only possible using a
commercially available thermocouple (connection type K),
which can be connected to the measuring tool via the
interface (25) intended for this.
Surface temperature can also be measured by touching a
surface with a thermocouple.
The light of this measuring tool is intended to illuminate the
direct work area of the measuring tool in order to take pic-
tures.
The laser points must not be used as a laser pointer. They
are solely for marking out the area being measured.
The measuring tool is suitable for indoor and outdoor use.