KMD 04
Digital multimeter

Diodes

Warning
Turn off all power and discharge all capacitors before testing diodes.
To test a diode:
1. Turn the rotary switch to the
diode mode.
2. Connect the red test lead to the
the COM jack.
3. Connect the red test lead to the anode (+) and the black lead to the
cathode (-) of the diode.
4. The display will show the forward biased voltage drop. If the leads are
reversed, the display nwill show OL.
In a circuit, a good diode will produce a voltage drop between .05~0.8V.
Reverse bias readings will depend on the resistance of the pathways between
the leads.

Continuity

Warning
Turn off all power and discharge all capacitors before testing continuity.
To test a continuity:
1. Turn the rotary switch to the
to continuity mode.
2. Connect the red test lead to the Ω input jack and the black test lead to the
COM jack.
3. Connect the leads to the circuit under test.
4. If the measured resistance is less than 50Ω, the buzzer will sound.
Instructions manual |
30
position. Press
input jack and the black test lead to
position. Press
www.grupotemper.com
once to switch to
twice to switch