Back View
8. Install the User Interface
IMPORTANT! Do not allow the cable routed through the wall hole to fall into the wall.
Push a thin nail into the groove in the back side of the user interface to separate the interface from
the mounting plate.
Position the mounting plate over the cable and against the finished wall so the hooks are to the left.
Level the mounting plate and mark the screw hole locations on the wall.
Remove the mounting plate and drill 1/4" holes at the marked locations.
Insert the provided wall anchors into the holes.
Apply a bead of 100% silicone sealant to the two grooves on the back of the mounting plate.
Position the mounting plate over the cable with the hooks to the left, and secure to the wall using
the two screws provided.
Check for level. If needed, loosen the screws and adjust the mounting plate.
Connect the cable to the user interface.
Engage the edge of the user interface with the two mounting plate hooks, then firmly swing the
user interface against the mounting plate until they snap together.
Refer to the User Guide included with the user interface to set up, program, and verify proper
function of the product.
Troubleshooting
NOTICE: This section is for general aid only. A Kohler Co. Authorized Service Representative or qualified
electrician should correct any electrical problems. For warranty service, call 1-800-4KOHLER from within
the USA and Canada, or 001-800-456-4537 from within Mexico.
NOTE: For service parts information, visit your product page at www.kohler.com/serviceparts.
Kohler Co.
Mounting
Plate
100% Silicone
Sealant
17
Front View
Pencil
Anchors
Screws
Horizontal and
Vertical
Adjustment
Hooks
User
Interface
1297610-2-B