Troubleshooting (cont.)
Heated Surface Troubleshooting Table
Symptoms
2.
Bath is on, but there is
little or no heat.
Kohler Co.
Probable Cause
B. Heated surface control must be
reset.
C. User interface cable connections
are loose or damaged.
D. Heated surface control does not
work.
E. Power supply does not work.
F.
User interface does not work.
A. Heater cable loose or damaged.
B. Heater/insulation loose on the
bath.
C. Heat indicator is set to low heat. C. Press the plus [+] icon to increase
D. Heater does not work.
E. Temperature sensor does not
work.
21
Recommended Action
B. If the red LED on the heated
surface control is not blinking,
unplug the control for 30 seconds,
then plug in and restart.
C. Inspect the cables between the user
interface, heated surface control,
and control amplifier. Secure
connections or replace cables as
needed.
D. Check the heated surface control.
Replace as needed.
E. Check the power supply. Replace
as needed.
F.
Check the user interface. Replace as
needed.
A. Inspect the cables between the user
interface, heated surface control,
and control amplifier. Secure
connections or replace cables as
needed.
B. Secure the heater/insulation to the
bath.
temperature.
D. Replace the heater.
E. Replace the heater.
1297610-2-B