Symptom
• If the display does not turn on or in
operation the display and the device
turn off.
• When turning on device or during
operation the display shows E0
alternating with CA (fault in return air
probe). During this error the device
works, but does not regulate return
air probe (and the temperature
cannot be raised or lowered). To
turn off press the ON/OFF button
once on the keyboard or the control.
• E6 flashes on the display.
• Fuse blown or unplugged (in 30A power
cable).
• Electronic control faulty.
• Power cable not connected,
with faulty contact or cut.
• Electronic control power fuse (15A)
disconnected or blown.
• Power cable polarity inverted.
• Bad connection on terminals or cables of
the return air probe.
• Return air probe disconnected or faulty.
• Bad connection on terminals or cables of
the anti-icing probe.
• Anti-icing probe disconnected or faulty.