TROUBLESHOOTING

Symptoms
The machine's anmeter does not
fluctuate .
The charger is properly connected
but it does not charge the battery
The anmeter's pin goes above the
maximum marking while the
device is set to minimum intensity.
The fuse blows every time it is
replaced
The fuse trips.
After charging for a whole day,
the end of charge indicator does
not switch on.
14
NEOSTART 320 / 420 / 620
Causes
Power supply problem.
Clamps in short circuit or polarity
reversal.
The battery that you are trying to
charge is faulty.
Voltage error (12 -24V)
Following intensive use, your device
has entered thermal protection mode.
Blown fuse
Bad clamp connections.
Wrong charge settings
Following intensive use, your device
has entered thermal protection mode.
The battery is deeply discharged.
Voltage error (12 -24V)
Your battery has elements in short
circuit.
Polarity reversal
Wrong charge settings
Current overconsumption on the
battery
The machine is charging a 12V battery
in 24V mode
Starts are attempted while the device is
in charge mode.
You are charging a 12V battery in 24V
mode
The battery is damaged
The machine is charging a 24V battery
in 12V mode
Remedies
Check your mains power supply.
Check that the device is on charge mode.
Check that the fuses have not melted and that the
circuit breaker is not tripped
Check the terminals' voltage with a voltmeter. If this
voltage jumps instantaneously to 2.5V per element,
the battery may be sulfated or damaged.
Chck that the switch is on the right setting (12 or
24V)
Wait 1/4h so the device can cool down.
Replace the fuse by a new one.
Clean the terminals and the clamps. Check the state
of the cables and clamps.
Check that the selected voltage matches the battery
voltage.
Wait 1/4h so the device can cool down.
Keep charging using the minimum setting .
Chck that the switch is on the right setting (12 or
24V)
Damaged battery Replace the battery.
Connect the + clamp to the battery's (+) and the +
clamp to the battery's (-).
Check that the selected voltage matches the battery
voltage.
Do not draw any of the battery's current during the
charge
Set the switch to 12V.
Make sure to set the switch to « start » to prevent
damage to the machine. Reset the circuit breaker.
Set the switch to 12V.
Change the battery.
Set the switch to 24V.