ELECTRICAL CONNECTIONS

- To avoid safety hazards or malfunctions, electrical control devices connected
to the motor must be rated according to the characteristics of the motor.
- Disconnect devices must be installed in the mains power supply line in accord-
ance with national installation regulations.
- If used outdoors, use a H05RN-F power cable with a minimum carbon content
of 2%.
- Do not use connecting cables between the selector and the motor that are
longer than 50 m.
- If the motor has to be controlled from a greater distance, use an isolating relay.
TM2 PP
1- brown
2- black
3- blue
4- yellow-green