OPERATING INSTRUCTIONS
Checking for Leaks
Afterallconnectionsaremade,checkallconnectionsandfittingsontheLPgastankvalve,gashose
and regulator for leaks with a water and soap solution.
Topreventfireorexplosionwhiletestingforaleak:
• Always perform leak test prior to lighting the grill.
• Do not smoke while testing for a leak.
• Always perform leak tests outdoors in a well-ventilated area.
•Donotuseanysourceofflamewhiletestingforleaks.
• Do not use the grill until any and all leaks are corrected.
• If you are unable to correct a leak, disconnect the propane supply and call a gas appliance service
dealer.
Perform Leak Test
• Prepare leak test solution by combining 1 part liquid dish soap with 3 parts water. Total solution
requiredisapproximately2-3ounces(70-90ml).Putleaktestsolutioninaspraybottle.
• Ensure all control knobs are in the O OFF position.
• Connect the gas hose to the gas supply.
• Open the LP gas tank valve.
• S prayleaktestsolutiononallgascarryingconnectionsandfittings.Presenceofbubblesatareasof
applied test solution indicates a gas leak. If leaks are detected or you smell or hear gas, shut off the
gas supply valve immediately and repair or replace the defective part. Do not use the grill until all
leaks are corrected.
Use only the regulator and hose assembly provided. If a replacement is necessary, please call our
customer service center. DO NOT use replacement parts that are not intended for this grill.
ALL INSTRUCTIONS AND SAFEGUARDS ON THIS PAGE MUST BE FOLLOWED TO
PREVENT FIRE, DAMAGE AND/OR INJURY.