Installation - Speedaire 10 HP Manual De Instrucciones De Operación Y Partes

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Speedaire
Operating Instructions & Parts Manual
Models 1WD87, 1WD88, 1WD90

Installation

Do not operate
unit if damaged during shipping,
handling or use. Operating unit
if damaged may result in injury.
1. Permanently installed
compressors must be located
in a clean, well ventilated dry
room so compressor receives
adequate supply of fresh,
clean, cool and dry air.
It is recommended that a
compressor, used for
painting, be located in a
separate room from that area
wherein body sanding and
painting is done. Abrasive
articles or paint, found to have
clogged the air intake filters
and intake valves, shall
automatically void warranty.
2. Compressors should never
be located so close to a wall or
other obstruction that flow of
air through the fan bladed
flywheel, which cools the
compressor, is impeded.
Permanently mounted units
should have flywheel at least
12" from wall.
For Service and Warranty, Call: 1-888-303-1344.
3. Place stationary compressors
on firm level ground or
flooring. Permanent
installations require bolting to
floor, and bolt holes in tank or
base feet are provided.
Before bolting or lagging
down, shim compressor level.
Avoid putting a stress on a
tank foot by pulling it tightly
down to floor. This will only
result in abnormal vibration,
and possible cracking of
Air Receiver. As an alternative,
install unit on optional
vibro-isolator pads. Tanks
bolted directly to a concrete
floor without padding will
not be warranted against
cracking.
Do not install
isolating valves between
compressor outlet and air
receiver. This will cause
excessive pressure if valve is
closed and cause injury and equip
ment damage.
air pressure regulating device
at the point of use. Failure to
do so can result in injury or
equipment damage.
WIRE SIZE (AWG)
75° Copper Conductor - 30° Ambient
Three Phase
HP
208V
10
8
15
4
Figure 1-1 Wiring Diagram
5
• Do not install in an area where
ambient temperature is below
32 degrees F or above
100 degrees F.
• Do not install unit in an area
where air is dirty and/or
chemical laden.
• Unit is not to be installed
outdoors.
Electrical Power Supply
It is essential that the power
supply and the supply wiring are
adequately sized and that the voltage
correspond to the unit specifications.
Branch circuit protection must be
provided at installation as specified in
the National Electrical Code.
All wiring should be performed by
a licensed electrician or electrical
contractor. Wiring must meet
applicable codes for area of installation.
The table below gives recommended
wire sizes based on the 1999 NEC.
All models require a properly sized
starter as specified in the National
Electric Code be provided at installation.
Always use an
The pressure switch must be wired to
the starter. See Figure 1-1 for wiring
diagram.
230V
460V
8
14
6
14
E
N
G
L
I
S
H

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

15 hp1wd871wd881wd90

Tabla de contenido