Installation Instructions - Speedaire 40HU29 Manual De Instrucciones De Operación Y Lista De Partes

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION INSTRUCTIONS

coolers. Do not use unit to lift other attached equipment.
Picking the Location
Install and operate unit at least 24 inches from any
obstructions in a clean, ventilated area. The surrounding
air temperature should not exceed 100° F or fall below
40° F. This will ensure an unobstructed flow of air to cool
compressor and allow adequate space for maintenance.
spray, sandblast areas or any other source of
contamination.
NOTE: If compressor operates in a hot, moist
environment, supply compressor pump with clean, dry
outside air. Supply air should be piped in from external
sources.
Tank Mounting
The tank should be bolted into a flat, even, concrete floor or on
a separate concrete foundation. Model 2LVP7 isolator pads are
recommended for this unit.
When using isolator pads, do not draw bolts tight. Allow the pads
to absorb vibrations. When isolators are used, a flexible hose or
coupling should be installed between the tank and service piping.
possible bursting.
8
Disconnect, tag and lock out power source then release all pressure from the
system before attempting to install, service, relocate or perform any maintenance.
Do not lift or move unit without appropriately rated equipment. Be sure the unit is
securely attached to lifting device used. Do not lift unit by holding onto tubes or
Never use the wood shipping skids for mounting the compressor.
Do not locate the compressor
air inlet near steam, paint
Failure to properly install the tank can
lead to cracks at the welded joints and
Figure 3 - Location
Figure 4 - Isolator Pad

Publicidad

Tabla de contenido
loading

Tabla de contenido