On the general menu TOP, there is access to the options: 1.USR and 2.FACT.
Select the option1.USR for access to the user menu:
TOP]  1. USR
+ -
2. FACT
On the user menu, the following options are available:
Menu uSr
1. DIAGNOSIS
Self-diagnosis of the protection unit
2. FREQUENCY
Confirmation of frequency
3. SETTING
Confirmation of set parameters on the front selectors
4. GND TRIP
(Not available in this model of protection unit.)
5. FAULT
Record of the last 10 faults which occurred
6. TEST
Test functions of the protection unit
1 DIAgnoSIS
USR]  1. DIAGNOSIS
+ -
2. FREQUENCY
DIA]  1. COIL: OK
+ -
2. EEP: OK
DIA]
1. COIL: OK
+ -  2. EEP: OK
HAZArD!
If on the DIAGNOSIS menu the display presents the message 1. CoIl:
Fail, contact WEG.
2 FreQuenCy
USR]
1. DIAGNOSIS
+ -  2. FREQUENCY
FREQ]
Freq: 60Hz
(50/60Hz)
ENT
ENT
Verification of the state of connection with the trip
coil: OK (normal) or Fail (fault).
Verification of EEPROM memory.
ENT
Confirmation of frequency.