7
COMMISSIONING
en
7.2

Check the application conditions:

28
O P E R A T I N G I N S T R U C T I O N S | RAY10
NOTE
The light band has to be positioned parallel to the conveyor belt.
It is important to ensure that the light band is positioned directly above the conveyor
belt, otherwise small objects may not be detected.
4
Tip:
1
Fine adjustment of the light band: Fold white A4 sheet twice. The light band must
be visible on both conveyor belt edges evenly in their entire height on the white
paper. The conveyor belt must not be in the light band. The light band must be
aligned in parallel without any gap over the conveyor belt. It should be noted that
the setting of the light band is minimal can change if the screws are tightened on
the bracket.
2
Note the triple structure of the reflector:
correct:
3
Control of the setting: Switch on conveyor belt. In "idling mode" (conveyor belt
moves without material to be conveyed), the sensor must not switch. Switch on
conveyor belt. Place the goods in succession on the conveyor belt edges and in the
middle on the belt to check the reliable detection in three places.
4
There is no feedback on the signal strength light bar for correct parallel installation
near the conveyor bottom.
Sensing range
Adjust the distance between the sensor and the reflector according to the correspond‐
ing diagram
see figure 18, page
4
not correct:
29.
4
8022198.1BXN / 2021-05-26 | SICK
Subject to change without notice