Special conditions for safe use: Refer to Hazardous area certification
Maximum exposure temperature: 110°C
Minimum exposure temperature: –60°C
Minimum installation temperature: –20°C
For use with the heating cable types as shown in the table below.
BTV/QTVR (Hazardous area)
ATEX
SGS20ATEX0048X
II 2 G Ex 60079-30-1 eb IIC T6 Gb
II 2 D Ex 60079-30-1 tb IIIC T80°C Db
BTV
II 2 G Ex 60079-30-1 eb mb IIC T6 Gb
II 2 D Ex 60079-30-1 mb tb IIIC T80°C Db
Tmin –60°C
SGS20ATEX0050X
II 2 G Ex 60079-30-1 eb IIC T4 Gb
II 2 D Ex 60079-30-1 tb IIIC T130°C Db
QTVR
II 2 G Ex 60079-30-1 eb mb IIC T4 Gb
II 2 D Ex 60079-30-1 mb tb IIIC T130°C Db
Tmin –60°C
FS-C-2X, FS-C10-2X (Non Hazardous area only)
WARNING: Please make sure the installation is carried out in clean,
dry conditions and all cable ends are protected from moisture.
Follow instructions carefully.
DEUTSCH
Randbedingungen für den sicheren Gebrauch: Beachten Sie die
Ex-Zulassungen
Maximale Einsatztemperatur: 110°C
Minimale Einsatztemperatur : –60°C
Minimale Verarbeitungstemperatur: –20°C
Für die Verwendung mit den Heizbändern entsprechend folgender Tabelle.
BTV/QTVR (Ex-Bereich)
ATEX
SGS20ATEX0048X
II 2 G Ex 60079-30-1 eb IIC T6 Gb
II 2 D Ex 60079-30-1 tb IIIC T80°C Db
BTV
II 2 G Ex 60079-30-1 eb mb IIC T6 Gb
II 2 D Ex 60079-30-1 mb tb IIIC T80°C Db
Tmin –60°C
SGS20ATEX0050X
II 2 G Ex 60079-30-1 eb IIC T4 Gb
II 2 D Ex 60079-30-1 tb IIIC T130°C Db
QTVR
II 2 G Ex 60079-30-1 eb mb IIC T4 Gb
II 2 D Ex 60079-30-1 mb tb IIIC T130°C Db
Tmin –60°C
FS-C-2X, FS-C10-2X (Nur für den Nicht-Ex-Bereich)
ACHTUNG: Bitte stellen Sie sicher, daß die Montage in sauberer und
trockener Umgebung erfolgt und die Kabelenden vor Feuchtigkeit geschützt
werden. Bitte die Anleitungen genau beachten.
IECEx
IECEx BAS.06.0043X
Ex 60079-30-1 eb IIC T6 Gb
Ex 60079-30-1 tb IIIC T80°C Db
Ex 60079-30-1 eb mb IIC T6 Gb
Ex 60079-30-1 mb tb IIIC T80°C Db
Tmin –60°C
IECEx BAS.06.0045X
Ex 60079-30-1 eb IIC T4 Gb
Ex 60079-30-1 tb IIIC T130°C Db
Ex 60079-30-1 eb mb IIC T4 Gb
Ex 60079-30-1 mb tb IIIC T130°C Db
Tmin –60°C
IECEx
IECEx BAS.06.0043X
Ex 60079-30-1 eb IIC T6 Gb
Ex 60079-30-1 tb IIIC T80°C Db
Ex 60079-30-1 eb mb IIC T6 Gb
Ex 60079-30-1 mb tb IIIC T80°C Db
Tmin –60°C
IECEx BAS.06.0045X
Ex 60079-30-1 eb IIC T4 Gb
Ex 60079-30-1 tb IIIC T130°C Db
Ex 60079-30-1 eb mb IIC T4 Gb
Ex 60079-30-1 mb tb IIIC T130°C Db
Tmin –60°C