Error Indication; Detailed Information - Omron E5AR Hoja De Instrucciones

Ocultar thumbs Ver también para E5AR:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

1. Input Allocation List
Input range
Input type
Set
Input type
switch
value
name
(˚C)
(˚F)
0
-300.0 - 1500.0
Set to TC.PT
Pt100(1)
-200.0 - 850.0
-199.99 - 300.00
1
Pt100(2)
-150.00 - 150.00
-300.0 - 2300.0
2
K(1)
-200.0 - 1300.0
3
0.0 - 900.0
K(2)
-20.0 - 500.0
4
-100.0 - 850.0
-100.0 - 1500.0
J(1)
TC.PT
0.0 - 750.0
5
J(2)
-20.0 - 400.0
6
-300.0 - 700.0
IN1
T
-200.0 - 400.0
TYPE
7
0.0 - 600.0
0.0 - 1100.0
E
-100.0 - 1500.0
8
L
-100.0 - 850.0
ANALOG
9
-300.0 - 700.0
U
-200.0 - 400.0
10
-300.0 - 2300.0
N
-200.0 - 1300.0
0.0 - 3000.0
11
R
0.0 - 1700.0
0.0 - 3000.0
12
S
0.0 - 1700.0
13
300.0 - 3200.0
B
100.0 - 1800.0
14
W
0.0 - 2300.0
0.0 - 4100.0
One of the following ranges is
Set to ANALOG
15
4 - 20mA
displayed by scaling.
16
0 - 20mA
TC.PT
-19999 - 99999
17
1 - 5V
-1999.9 - 9999.9
IN1
18
0 - 5V
TYPE
-199.99 - 999.99
19
0 - 10V
-19.999 - 99.999
ANALOG
-1.9999 - 9.9999
The default settings are Set Value: "2", Input Type SW: "TC.PT".
3. Alarm type list
Alarm output function
Alarm type
Positive alarm value (X) Negative alarm value (X)
0 No alarm function
Output OFF
L
H
ON
1
Always ON
Upper/lower limit
OFF
SP
X
ON
ON
2
Upper limit
OFF
OFF
SP
X
ON
ON
3
Lower limit
OFF
OFF
SP
L
H
Upper/lower limit
ON
4
Always OFF
range
OFF
SP
Upper/lower limit
L
H
with standby
ON
5
Always OFF
OFF
sequence
SP
X
Upper limit with
ON
ON
6
standby sequence
OFF
OFF
SP
X
Lower limit with
ON
ON
7
standby sequence
OFF
OFF
SP
X
Absolute-value
ON
ON
8
upper-limit
OFF
OFF
0
X
Absolute-value
ON
ON
9
OFF
lower-limit
OFF
0
Absolute-value
X
ON
ON
upper-limit with
10
OFF
OFF
standby sequence
0
Absolute-value
X
11
ON
ON
lower-limit with
OFF
OFF
standby sequence
0
1:Upper and lower limits can be set for parameters 1, 4 and 5 to provide for
different types of alarm. These are indicated by the letter "L" and "H".
9
Input type switch (bottom)
2. Output Type List
Linear current
Output type
output type
Set
Set
Output range
Name
value
value
Pulse
0
output
0
0 - 20mA
Linear
1
output
1
4 - 20mA
The default setting is "0".
4. Auto tuning
The timing for generating the limit cycle
varies depending on whether or not the auto
tuning start deviation (DV) is below 10% FS.
The action of auto tuning PV is as follows:
Deviation ≥ 10% FS
Limit cycle
Present
Change in manipulation
value
value of 40%
Set
value
10% FS
deviation
Time
X
AT ends
AT starts
SP
Deviation < 10% FS
Present
Limit cycle
value
X
Change in manipulation
value of 40%
Set
SP
value
10% FS
deviation
Time
AT start
AT end
X
SP
However, PV action is as follows during
X
ON/OFF control, heating/cooling control,
SP
and position proportional control (floating).
X
Limit cycle
0
Change in manipulated
Present
X
variable of 100%
value
0
Set
X
value
0
X
0
Time
AT start
AT end

Error Indication

Display 1 Display 2 Error description
err
Unit error
Repair is necessary.
unit
Contact your dealer or our service office.
unit
chg
Unit change
Press the
key for at least 5 s. to register the new
Unit configuration.If you cannot clear the error, contact
your dealer or our service office.
disp
err
Display unit error
Repair is necessary.
Contact your dealer or our service office.
sys
err
Main unit error
eep
err
Press the
key in this state for at least 5 s. to return
Non-volatile
to the factory settings.
memory error
s.err
Verify that there are no incorrect input connections,
Normal
Input error
broken circuits, or short circuits. Check the input types
display
and the switches for each input type.
[[[[[
Outside display
This is not an error, however, the present value is
Normal
range (below)
outside of the display range (-19999 to 99999).
display
]]]]]
Outside display
range (above)
The RSP run
Check and see if the wire to the RSP input is broken or
Normal
RSP input error
indicator
shorted.
display
is blinking
-----
Normal
Potentiometer
Check the potentiometer wire.
display
input error
calb
err
Motor calibration
Check the wiring to the potentiometer and the valve drive
error
motor, and then repeat motor calibration.
i1-t
A set
Input type switch
Make sure the input type switch and the displayed
i2-t
value
error
"Input type" setting accord with the input type you will
i3-t
flashes
use.
i4-t
If the system does not operate as desired when you check operation after completing the settings,
check the connections and set values once again. If operation is still not correct, an incorrect
setting may exist for an unintended setting. It is possible to initialize and then newly configure this
device.
All settings on this device can be returned to factory setting by initialization.
You may not be able to obtain desirable output results under the factory
setting. Initialize this device after eliminating any influences to your system by
CAUTION
disconnecting wires on output unit or performing other conceivable measures.
Before initialization, take notes of the setting values.
For more information on initializing the unit, see the "E5AR/ER User's
Manual".

Detailed Information

1. This manual contains instructions for installing the product and information on basic operation. For
information on applications such as heating/cooling control and position proportional control,
detailed explanations of communication settings and parameters, and troubleshooting, refer to the
following User's Manuals.
E5AR/ER User's Manual (English)
Refer to the following operation manuals for details on using DeviceNet communications.
E5AR/ER Digital Controller DeviceNet Communications User's Manual (English) Cat. No. H124
Output state at error
Remedies
Control output Alarm output
OFF
OFF
OFF
OFF
MV is output
Same operation
according to
as when upper
the "MV at PV
limit is
error" setting.
exceeded.
Normal
operation
Normal
operation
Normal
display
OFF
OFF
Cat. No. Z182
OFF
OFF
OFF
OFF
Normal
operation
Normal
operation
Normal
display
OFF
OFF
10