Installation To Wood Stud Wall - PEERLESS SmartMount SA740P Instalación Y Montaje

Ocultar thumbs Ver también para SmartMount SA740P:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation to Wood Stud Wall

• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and
components.
Remove cord covers from wall arm assembly (A) as shown in figure 1.1. Using a stud finder, locate and mark the
1
edges of the wood stud used in mounting this product. Use of an edge to edge stud finder is highly recommended.
Use a level to draw a vertical line down the center of the stud. Use wall plate as template to mark center of holes
along the vertical line. Drill two 5/32" (4 mm) dia. holes 2.5" (65 mm) deep. Attach wall mount (A) to wall using two
#14 x 2.5" flat head wood screws (H) as shown in figure 1.2.
Skip to step 2 on page 6.
• Tighten screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the screws,
greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the studs. The use of an "edge to edge" stud finder is
highly recommended.
CORD COVER
A
WARNING
WARNING
fig. 1.1
A
H
4 of 30
fig. 1.2
ISSUED: 07-12-06 SHEET #: 095-9234-9 02-22-07
WOOD
STUD
WALL

Publicidad

Tabla de contenido
loading

Tabla de contenido