Make the electrical connections and connect
the air outlet pipe; place the ceiling-mounted
hood into the niche, by inserting the threaded
bars into the holes (Fig.6); the outer edge of
the hood needs to be perfectly flush with the
false ceiling. Insert the plates and nuts pro-
vided into the threaded bars, making sure to
tighten them securely (Fig. 7); refit the grease
filters and filter cover panels.
Connect the internal motor or the external
motor's cable to the terminal board found in-
side the plastic box of the wiring . Make sure
to respect the colors of cables when perfor-
ming the electrical connection (fig.20).
SLT950 EM - SLT951 EM - SLT952 EM -
SLT953 EM WITH INTERNAL MOTOR (Fig.22)
With Internal motor models, the same instal-
lation procedure as for the external motor
version (EM) can be followed, but with some
differences.
If the appliance is Internal motor air capacity
suctioning unit, a minimum distance of at le-
ast 410mm between the ceiling and the false
ceiling needs to be maintained with SLT950,
SLT951 and
SLT953 models. The SLT952
model requires a minimum distance of at le-
ast 450mm between the ceiling and the false
ceiling.
Threaded bars of the length of 400mm are
supplied with the suctioning unit.
The SLT952 model requires a minimum di-
stance of at least 520mm between the ceiling
and the false ceiling.
Threaded bars of the length of 400mm are
supplied with the suctioning unit.
Remove the plug in the upper part of the
appliance and fit the suctioning unit. (see
fig.12).
Connect the motor electric cable to the suita-
ble connector found inside the cooker hood ,
orient the air out-let flange towards the de-
sired direction and fix the motor to the coo-
ker hood body by using the screws previously
removed.
If it is necessary to orient the air out-let up-
wards, please remove the plug shown in fig.
13.
Remove the motor fixing screws ,pull the mo-
tor out, rotate it and then insert it in the out-
let hole just opened and fix it by using the
screws previously removed.
Unused holes must be closed with the suita-
ble plug.
Carry out the installation as shown for the
external motor version, but taking into ac-
count the details above.
SLT950.1 – SLT951.1 - SLT958.1 (internal
motor) (Fig.23)
Fit a false ceiling with an opening that has the
following dimensions:
SLT950.1: 1465x965 mm with a minimum
distance of 330 mm between the ceiling and
the false ceiling;
SLT951.1: 1065x665 mm with a minimum
distance of 330 mm between the ceiling and
the false ceiling
SLT953.1: 1065x665 mm with a minimum
distance of 190 mm between the ceiling and
the false ceiling;
SLT958.1: 865x405 mm with a minimum di-
stance of 330 mm between the ceiling and
the false ceiling
It is possible to select the side of the cooker
hood where the air suctioned can be dischar-
ged, as follows:
SLT 953.1: on this model the air outlet is on
one side only (see pic. 21)
Remove the eight fixing screws of the suc-
tioning unit shown in fig. 16, pull the suc-
tioning unit out by disconnecting the electric
connector , remove the cover of the air out-
let hole you want to use and place the suc-
tioning unit . Restore the electric connec-
tion and secure the suctioning unit with the
screws previously removed . Refit the cover
on the unused air out-let hole.
Carry out the installation following the pro-
cedure shown for SLT950 EM, SLT951 EM,
SLT958 EM and SLT953 EM models.