Setting the torch ID
Each torch in the i-LTG/i-LTW has a specific torch
identification number. This torch ID is coupled to
the load capacity of the torch, which is required
for the torch protection function in the TIG oper-
ating mode.
‰ Setting the torch ID is, for example, required
when the torch PC board is exchanged.
 Select the item (Tor) in the configuration menu.
 Select the menu item "TPd".
‰ The currently selected torch ID is shown.
 Select the appropriate ID for the torch accord-
ing to the following table and transfer it to the
torch module by pressing the control knob 19.
Torch ID
Type of torch
Torch ID
i-LTG 900
i-LTG 1700
i-LTG 2600
i-LTG 2800
i-LTW 3000
i-LTW 1800
i-LTW 1800sc
i-LTW 2000
i-LTW 4500
Tab. 4:
Torch ID

18 Special functions

Master Reset
Caution! All personal settings will be
i
lost.
All stored jobs are retained!
All welding and secondary parameters
as well as the machine configuration
are reset to master reset values.
 Press buttons 26 and 29 simultaneously for at
least 5 seconds.
- 38 -
Loading capacity
DC
9
125 A
17
150 A
26
200 A
28
300 A
30
320 A
18
350 A
19
400 A
20
220 A
45
450 A
9 The 7-segment display and the control panel
indicators light up briefly for confirmation and
the system restarts.
19 Torch
Powermaster torch of i-LTG/i-LTW series
Torch switch functions
75
Torch switch Start/Stop
for starting and stopping the welding
process.
76
Torch switch second current
for calling up the second current.
Torch button Up
77
to increase parameter values
78
Torch button Down
to reduce parameter values
80
LED Ampere:
AC
Lights up when the display (84) shows the
welding current.
80 A
81
Job LED:
120 A
Not available for BasicPlus!
160 A
82
Powermaster LED 3:
Can be allocated to freely selectable pa-
250 A
rameter.
220 A
Pre-set to secondary current I2.
250 A
83
Powermaster LED 4:
Can be allocated to freely selectable pa-
320 A
rameter.
165 A
84
Display: Presentation of the parameter
360 A
values.
85
Mode button:
Switching between parameters LED 80 to
LED 83
7 sec. Press to switch the display (84) be-
tween right- and left-hand mode. A point
is shown in the right, bottom of the display
as index.
The "Mode" button is unlocked for 15 sec.
by pressing it for 2 sec. (when the "Power-
master LED lock" (PLL) secondary parameter
is activated).
909.4039.9-03
IX
Torch
04.19

Publicidad

Tabla de contenido
loading

Tabla de contenido