Filter element replacement

Where appropriate, close shutoff valves at gas
inlet and outlet or depressurize the sytem.
Depressurize the housing : open the needle
valve (1)
Where required, separate the condensate discharge duct
from the needle valve (1).
unscrew fixing screw (2).
Unscrew the lower part of the filter (3), check the O-
ring and the distance ring (6) and replace it if required.
Remove the old filter element (4) and insert new one.
Caution: The filter elements FHP 261 and 371 are
equipped with a thread. Any other filter elements may
be detached and are supported from the floor up using
a spacer plate (5).
Close the housing, retighten the self-locking bolt (2),
close the needle valve (1).
Where required, connect the condensate discharge
duct with the needle valve (1).
Slowly admit pressure to the filter by gradual opening
of the shutoff valves.
Check the tightness of the housing and of the needle
valve.
Make a note of the date of the next element replace-
ment on the maintenance schedule and the label
supplied with the elements. Stick the label on a part
of the filter housing where it can easily be seen. Re-
order new elements and, where appropriate, a new
float-type drain to ensure an adequate stock of spare
parts (see Appendix, Fax Request).
Ensure correct disposal of old filter elements in ac-
cordance with the applicable waste disposal key.
061302 Used activated carbon
150203 Absorbing and filter materials,
wiping cloths and protective clothing
(with the exception of 150202:
contaminated with hazardous substances)
CLEARPOINT HP 100 S040-M020, HP 350 S030-M015, HP 500 S030-S050
english
additional, 180° offset
threaded hole for
fixing screw to allow
different installation
position
2
Fixing screw
4
Filter element
/
(FHP 361
371 with
threaded connection)
5
Distance plate
/
(not with FHP 261
371)
6
O-Ring
(with distance ring,
where required))
3
Filter bottom
1
Needle valve with re-
strictor
9