CPV...-GE-MP-...
5

Technical data

WARNING
Use only power units which guarantee safe electrical
isolation of the operating voltages with at least 4 kV isolation
resistance as per IEC 742/EN 60742/VDE 0551. Switch po-
wer units are permitted providing they guarantee safe
isolation as per EN 60950/VDE 0805.
Type
Dimensions
Number of valve outputs
Control voltage
Drop-out current of the val-
ves
Protection class
Ambient temperature
Storage temperature
Tightening torque
- fastening screws for
connector plate
- multipin socket
Materials
Electromagnetic immunity
9708A
CPV..-GE-MP-...
See pneumatics manual
8, 12, 16
DC 24 V + 10%/-15% (20.4 - 26.4 V)
> 2 mA
IP 65 with cable from
FESTO accessories
IP 40 with commercially-available cable
IP 20 basic unit without cable
o
o
-5
... + 50
C
o
o
-20
... + 70
C
- for CPV10 and CPV14: 1,0 ± 0,2 Nm
for CPV18:
- 0,6 Nm
LABS-free, Al, St, NBR, Zn, PA, PC
as per EN 50082-2
2,9 ± 0,1 Nm