34. Connect end of hose to heat exchanger A.
Attach clamp (PN 3863439). Using a 5/16 in.
(8mm) socket, tighten screw to 20–32 in. lbs.
(2.3–3.6 Nm).
23508
35. Attach coolant reservoir overflow tube B
(PN 3860955) to the brass hose fitting on top of
the thermostat housing C. Attach clamps
(PN 3853794). Using a 1/4 in. (6.5mm) socket,
tighten bolts to 17–27 in. lbs. (1.9–3.1 Nm).
23509
36. Fasten coolant reservoir cap (PN 1674083) and
affix decals D (PN 3861505) and E
(PN 3858552) as illustrated.
23510
17