Every Second Hour - Chicago Pneumatic RX 2 Instrucciones De Operación Y Seguridad

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 70
Safety and operating instructions
11. Close gas bottle valve (A).
Checking and reducing the gas pressure
1. Always use the gas hose (C) and the pressure
gauge (D) when checking the gas pressure.
2. Connect the gas hose to the pressure gauge.
3. Remove the plug from the charge valve (G).
4. Press the nozzle of the gas hose into the charge
valve and read the pressure.
5. Reduce the pressure by repeatedly inserting and
removing the nozzle.
NOTICE
Only the nozzle may be used to reduce
the pressure. Never use pins, screwdrivers etc. as
these can damage the charge valve.

Every second hour

Regularly lubricate the insertion tool, the tool
retainer and the bushings.
Lubricating with a grease gun
WARNING
Hot insertion tool during
operation and a period of time after use.
Avoid contact with the insertion tool.
WARNING
Hot hydralic breaker during
operation and a period of time after use.
Avoid contact with the hydralic breaker.
20
CAUTION
Skin eczema
Grease can cause eczema when it comes in contact
with the skin.
Avoid getting grease on your hands. Wash
thoroughly after contact.
1. Press the insertion tool against the piston so that
the space between the piston and the insertion
tool does not fill with grease.
2. Lubricate the insertion tool's shank plentifully
while pressing the insertion tool against the
surface to avoid filling the cavity with grease. If
the cavity is filled with grease when the hydraulic
breaker is started, the lower seals may be
damaged.
When the insertion tool shank is exposed to high
pressure and high temperatures a standard type of
grease will melt and run. To avoid this always use a
genuine insertion tool grease from your supplier.
Central lubrication system
We recommend Chicago Pneumatic's central
lubrication system. When this system is fitted on the
carrier, grease is pumped continuosly from a
lubrication container on the carrier to the breaker
when the breaker is activated. This increases the life
of the tool bushings and insertion tools considerably.
9800 1050 90 | Original instructions
RX 2, 3, 4, 6, 8

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rx 3Rx 4Rx 6Rx 8

Tabla de contenido