SICK HTF18 Instrucciones De Operación página 12

Ocultar thumbs Ver también para HTF18:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 114
6
ELECTRICAL INSTALLATION
12
Time delay
The sensor may be specified with an adjustable time delay. The delay
time is adjusted by rotating the 270° potentiometer.
Clockwise rotation in the direction of the "+" printed on the sensor will
increase the delay time (T
clockwise stop position.
Counter clockwise rotation in the direction of the "-" printed on the
sensor will decrease the delay time. There will be no time delay at the
counter clockwise stop position.
CAUTION
Over rotation of the potentiometer past the stop positions will cause permanent dam‐
age to the sensor.
A L/D selection switch may be specified with an adjustable time delay. Adjustable time
delay does not impact a Health or Alarm output (if specified).
Table 5: Output ACTIVE states for complimentary output variants with adjustable time delay
HTX18-Pxxxx_
HTX18-Nxxxx_
HTX18-Fxxxx_
Q1 = L.ON
No Time Delay
Q2 = D.ON
Q1 = L.ON
-xxxxxC
-xxxxxF
-xxxxxI
2
-xxxxxM
Q2 = D.ON
Adjustabl
e ON
Delay
1
Q1 = D.ON
-xxxxxI
3
Q2 = L.ON
-xxxxxD
Adjustabl
-xxxxxG
Q1 = L.ON
e OFF
-xxxxxK
2
Delay
1
-xxxxxN
). Maximum Delay time will occur at the
DELAY
8017858.16K9 | SICK
Subject to change without notice

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Htf18l

Tabla de contenido