OPERATION
Controls
The hood is operated using the (4) push-
buttons located at eye-level, on the front edge
of the hood.
The light switch turns the halogen lights on
and off. Push the light switch once to turn
the lights ON - push a second time to turn
the lights ON to a brighter level - push a
third time to turn the lights OFF.
The timer switch turns the blower timer on and off. Push this switch once to turn the
timer ON. With the blower timer turned ON, the speed that was selected will blink in
the display; if the speed selection is changed the blower timer will remain ON; the
blower will shut OFF after 5 minutes.
The display indicates:
- indicates the selected motor speed (from 1 to 4);
- indicates Timer On when the number blinks;
- indicates Filter Alarm when the central segments is on or blinking.
The blower switch turns the blower on and off. Push the switch once to turn the
blower ON (turns on to last speed selected). Pushing the switch sequentially selects
blower speeds from 1 to 4. To turn OFF the blower, push and hold the blower switch
for approximately 2 seconds.
The reset switch resets the grease filter or charcoal filter alarm. The grease filter
must be cleaned when the center segment of the display lights up continuously or
blinks. When the center segment blinks, the grease filter needs to be cleaned and if
applicable the charcoal filter should be replaced (only applicable when hood is
installed for non-ducted recirculation). The filter alarm will be seen in the DISPLAY for
approximately 30 seconds after the blower is turned off. To reset the hour counter,
keep the switch pressed for 2 seconds when the alarm can be seen in the DISPLAY.
HALOGEN BULBS
This range hood requires two halogen bulbs
(Type T4, 12V, 20W).
ALWAYS SWITCH OFF THE ELECTRICITY
SUPPLY BEFORE CARRYING OUT ANY
OPERATIONS ON THE APPLIANCE.
To change bulbs:
1. Open the cover by prying from the proper
slots. - DO NOT ROTATE. CAUTION:
BULB MAY BE HOT!
3. Replace with a Type T4, 12V, 20W bulb.
Do not touch replacement bulb with bare
hands! If the bulb is touched with the bare
hand, it should be cleaned with a lint-free
cloth moistened with methylated spirit.
LIGHT
SWITCH
TIMER
SWITCH
- 10 -
DISPLAY
RESET
SWITCH
BLOWER
SWITCH