Operating conditions

This product is an Uninterruptible
Power Supply (UPS) for computers
and their peripherals, television
sets, stereo systems and video
recorders... It must not be used to
supply other electrical equipment
(lighting, heating, household
appliances, etc.).
UPS can be installed in horizontal,
vertical position, or placed in Rack
2U (optional kit).

UPS connections

Connect the UPS 1 to the
AC-power system via a wall outlet
with an earth connector, using the
supplied cord 2 .
Plug critical equipment
(computer, monitor, modem, etc.)
into the outlets
9 providing
battery backup power and surge
protection (see figure B), taking
care not to exceed the rated current
indicated in amperes.
Other devices (printer, scanner,
fax, etc.) can be connect to the
filtered outlet 10 that provide
surge protection (see figure B).
The filtered outlet is not backed up
by battery power in the event of a
power outage.
Optional Internet modem /
Network connection:
A modem or Ethernet data line
can be protected against surges by
connecting it via the UPS. Connect
the existing device cable between
the wall outlet and the UPS, and
use a similar cable between the
UPS and the device, as indicated in
figure C (cable not supplied).
Register for the warranty on the
www.eaton.com site (see figure E).
Operation
6 : Telephone outlet.
7 : LED ON indicates that surge
protection is active on all four
outlets.
8 : ON/OFF button for the battery
backup outlets.
9 : Battery backup outlets.
10 : Filtered outlet.
11 : Protection circuit breaker.
Battery charge: The UPS
charges the battery as soon as
it is connected to the AC outlet,
whether button 8 is pressed or
not. When used for the first time,
the battery will only provide its
maximum autonomy after it has
been charged for 8 hours. It is
recommended that the UPS be
permanently connected to the AC
power supply to ensure the best
possible autonomy.
6
Switching-on the UPS: press
button 8 for about 1 second.
Filtered outlet 10 without
battery backup: Equipment
connected to this outlet is supplied
as soon as the AC cord 2 is
plugged in. It is not affected by
button 8 .
Battery backup outlets 9 :
Equipment connected to these
outlets is supplied as soon as
button 8 turns green (see figure
E). These outlets can be turned on
even if the UPS is not connected to
AC power (button 8 flashes).
��
AC-power disturbance: If AC
power is disturbed or fails, the UPS
continues to operate on battery
power. Button 8 flashes green.
The audio alarm beeps every five
seconds, then every two seconds
when the end of battery backup
time is near.
If the power outage lasts longer
than the battery backup time, the
UPS shuts down and must be
restarted by pressing button 8
when power is restored. Following
a complete discharge, a few hours
are required to recharge the battery
back to full backup time.
To save battery power, it is
possible to press button 8 to cut
the supply of power to the devices
connected to the battery backup
outlets.
Lightning protection: All outlets,
whether backed up or simply
filtered, include surge protection,
whatever the position of button 8 .
Shutdown of the battery backup
outlets 9 : Press button 8 for
more than two seconds.
Battery disposal and safety
Caution. Battery service life is
reduced by 50% for every ten
��
degrees above 25°C.
The battery elements must be
replaced exclusively by qualified
personnel (risk of electrocution),
with new elements approved by
��
EATON to ensure correct operation
of the UPS.
��
The battery must be disposed
of in accordance with applicable
regulations. To remove the battery
elements, shut down the UPS
(button 8 OFF), remove the power
cord and proceed as indicated in
page 4 "Battery change".
Warning: take care not to inverse
the polarity + (red) and - (black)
when connecting the batteries as
this will destroy the device.
��