Grundfos GRA1031 Instrucciones De Instalación Y Funcionamiento página 5

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12
3. Mounting and setting of dosing
monitor
1. Mount the dosing monitor.
2. DME/S 2 to 48: Connect the dosing monitor, see
fig. A, page 40.
DME 60 to 940: Connect the dosing monitor, see
fig. B, page 41.
3. Activate the monitor input in the "SETUP" menu.
The function can be checked by letting air into the
suction tube. This makes the pump change over to
alarm mode (requires a certain counter pressure).
Fig. 3
DME 60 to 940
4. Disposal
This product or parts of it must be disposed of in an
environmentally sound way:
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest
Grundfos company or service workshop.
OK
Fig. 2
DME/S 2 to 48
Subject to alterations.
5

Publicidad

Tabla de contenido
loading

Tabla de contenido